Abstract
AbstractThe multicolumn continuous chromatographic separation process that increases throughput, purity, and yield compared to batch chromatography is considered as an important preparative technique to purify pharmaceutical drugs. Mitotane is a chiral drug marketed in the racemic form but pharmacological effects due to molecule chirality indicate that one of the enantiomers is more potent. Preparative separation of the mitotane enantiomers was performed by a continuous Varicol unit operated on a scale of 30 g/day. Amylose tris(3,5‐dimethylphenylcarbamate) functioned as the stationary phase and acetonitrile‐isopropanol mixtures as mobile phases. The enantiomeric purities obtained were 97.0 % for S‐(–)‐mitotane and 96.8 % for R‐(+)‐mitotane in the raffinate and extract streams, respectively. The unit provided productivities of 1.14 kg raffinate per day and kg adsorbent and 0.68 kg extract per day and kg adsorbent.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.