Abstract
This study aimed to determine whether choroid plexus volume (CPV) could differentiate multiple sclerosis (MS) from its mimics. A secondary analysis of two previously enrolled studies, 50 participants with MS and 64 with alternative diagnoses were included. CPV was automatically segmented from 3T magnetic resonance imaging (MRI), followed by manual review to remove misclassified tissue. Mean normalized choroid plexus volume (nCPV) to intracranial volume demonstrated relatively high specificity for MS participants in each cohort (0.80 and 0.76) with an area under the receiver-operator characteristic curve of 0.71 (95% confidence interval (CI) = 0.55-0.87) and 0.65 (95% CI = 0.52-0.77). In this preliminary study, nCPV differentiated MS from its mimics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Multiple sclerosis (Houndmills, Basingstoke, England)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.