Abstract

A direct aspiration first pass technique (ADAPT) is an effective thrombectomy option in patients with acute ischemic stroke. Balloon guide catheters (BGC) seem to improve the efficacy of stent retrievers and ADAPT. The last generation 6F aspiration catheters require 9F BGCs, which are rigid devices that are challenging to position in a tortuous anatomy. In this experimental study the efficacy of 6F ADAPT alone and 5F ADAPT combined with 8F BGC was evaluated. Either a fibrin rich (white) clot or an RBC rich (red) clot was placed in the M1 segment of a transparent silicon phantom. Physiological hemodynamic conditions were maintained. The clots were retrieved by 6F aspiration catheter via 8F long sheath or 5F aspiration catheter via a flexible 8F BGC. Thrombectomy was performed under direct visual control. The primary endpoints were the number of passes and the number of distal emboli. Ten experiments were made with each clot model and thrombectomy technique (n = 40). Full recanalization could be achieved in every experiment. First pass mTICI 3 could be achieved by 6F ADAPT in 80 % of red clots and 90 % of white clots. Distal emboli were caused in 10 % and 20 %, respectively. When using 5F ADAPT combined with BGC, a first pass mTICI 3 rate of 90 % in red clots and 100 % in white clots could be achieved. A 10 % rate of distal emboli occurred in both groups. In almost all experiments (both techniques), the thrombi clogged the aspiration catheter. No statistically significant differences could be found between the techniques and clot models. 6F ADAPT without BGC was as effective as 5FADAPT combined with a flexible 8F BGC, with both techniques showing high first-pass recanalization rates and low distal emboli rates. Especially in the case of a tortuous anatomy, these setups should be considered as alternatives to a rigid 9F BGC. The thrombus compositions seemed to be irrelevant in this setting. · 6F ADAPT with no BGC and 5F ADAPT with BGC were very effective and performed equally.. · Both techniques should be considered in tortuous anatomy.. · In this setting the clot composition showed no effect on the recanalization rate.. · Madjidyar J, Nerkada L, Larsen N et al. Choosing an Effective and Safe Direct Aspiration Setup for Tortuous Anatomy in Acute Ischemic Stroke: In vitro Study in a Physiological Flow Model. Fortschr Röntgenstr 2021; 193: 544 - 550.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call