Abstract

To determine the preferred infusion-sampling mode for isotopic studies of free fatty acid (FFA) metabolism, tracer [( 14C]palmitate) was infused into the left ventricle of five anesthetized dogs, and tracee ([3H]palmitate) was infused into three separate peripheral veins of each dog. The [14C]palmitate specific activity (SA) was lower in mixed venous than arterial blood, and [3H]palmitate SA was equal in both sites. The actual infusion rate of [3H]palmitate [2.15 +/- 0.31 X 10(5) disintegrations/min (dpm).kg-1.min-1] could be accurately predicted (2.14 +/- 0.32 X 10(5) dpm.kg-1.min-1) using the known [14C]palmitate infusion rate and the arterial plasma [14C]-to-[3H]palmitate ratio. In contrast, the mixed venous [14C]-to-[3H]palmitate ratio resulted in overestimates (P less than 0.05) of the actual [3H]palmitate infusion rate. In summary, venous tracer infusion with arterial blood sampling for FFA tracer studies provides the most accurate estimates of tracee rate of appearance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.