Abstract

Abstract— It was shown that chlorophyll a and its epimer chlorophyll a' are chlorinated and hydroxyl‐ated during thin layer chromatography with silica gel plates. Hydroxylated chlorophyll a could not be chlorinated. Chlorinated and non chlorinated chlorophylls could be separated and determined by high performance liquid chromatography, because chlorophylls do not alter during this procedure. These findings support the assumption that Chi RC I is a preparation artifact. The extent of chlorination depends on chloride availability on the thin layer and on time. Chlorination and hydroyxlation do not take place under nitrogen atmosphere. The mechanism of chlorination during the thin layer chromatography procedure is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have