Abstract
The effect of the chloride‐to‐sulfate mass ratio (CSMR) on lead leaching from 50:50 lead–tin solder galvanically coupled to copper in stagnant conditions was examined using bench‐scale testing and data from water utilities. The CSMR was significantly altered by coagulant changeover, blending of desalinated seawater, anion exchange, and NaCl brine leaks from onsite hypochlorite generators. Consistent with previous experiences, increasing the CSMR to the range of 0.1 to 1.0 produced dramatic increases in lead leaching from lead–tin solder galvanically coupled to copper. Before implementing any treatment changes that could increase the CSMR, utilities may want to use the protocol described in this article to ascertain the relative effect of the changes on lead corrosion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.