Abstract
Reinforced concrete structures may be exposed to an aggressive environment. In this case combined mechanical and environmental actions may act simultaneously and their synergetic influences have to be taken into consideration. In this contribution results of tests on two different types of concrete and mortars are presented and discussed. Capillary absorption of not carbonated and carbonated concrete has been determined. The influence of mechanical load on capillary suction has been studied separately. A moderate compressive load reduces the coefficient of capillary suction, while capillary suction is enhanced by higher mechanical loads as micro-cracks are formed. Chloride diffusion has been measured by means of the diffusion cell test. The diffusion coefficient observed in carbonated concrete is roughly speaking one order of magnitude higher than the value measured on not carbonated concrete.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.