Abstract
A coherent three-dimensional (angle-angle-range) lidar imager using a master-oscillator-power-amplifier concept and operating at a wavelength of 1.5 microm with chirp-pulse compression is described. A fiber-optic delay line in the local oscillator path enables a single continuous-wave semiconductor laser source with a modulated drive waveform to generate both the constant-frequency local oscillator and the frequency chirp. A portion of this chirp is gated out and amplified by a two-stage fiber amplifier. The digitized return signal was compressed by cross correlating it with a sample of the outgoing pulse. In this way a 350-ns, 10-microJ pulse with a 250-MHz frequency sweep is compressed to a width of approximately 8 ns. With a 25-mm output aperture, the lidar has been used to produce three-dimensional images of hard targets out to a range of approximately 2 km with near-diffraction-limited angular resolution and submeter range resolution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.