Abstract

Active frequency-chirp control for a narrowband pulsed titanium-sapphire laser oscillator-amplifier laser system is demonstrated using an intra-cavity electro-optic modulator, resulting in improved spectral resolution and stability. Beat-note measurements of its output to a continuous-wave laser locked to an optical frequency comb yields an Allan deviation of 5×10-11 (at 10 s). Correction of residual chirp from a comparison with the fourth-harmonic upconverted pulsed output to a molecular H2 two-photon resonance delivers a value for the uncertainty contribution due to frequency chirp below the 1.5×10-10 level.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.