Abstract
In the present study, a very simple CE method for chiral separation and quantitation of zwitterionic cetirizine (CTZ), as the main metabolite of hydroxyzine (HZ), and HZ has been developed. In addition, the effect of zwitterionic property of CTZ on enantioseparation was investigated. Maltodextrin, a linear polysaccharide, as a chiral selector was used and several parameters affecting the separation such as pH of BGE, concentration of chiral selector and applied voltage were studied. The best BGE conditions for CTZ and HZ enantiomers were optimized as 75 mM sodium phosphate solution at pH of 2.0, containing 5% w/v maltodextrin. Results showed that, compared to HZ, pH of BGE was an effective parameter in enantioseparation of CTZ due to the zwitterionic property of CTZ. The linear range of the method was over 30-1200 ng/mL for all enantiomers of CTZ and HZ. The quantification and detection limits (S/N=3) of all enantiomers were 30 and 10 ng/mL, respectively. The method was used to quantitative enantioseparation of CTZ and HZ in spiked human plasma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.