Background Left-sided breast cancer radiotherapy may increase the risk of cardiovascular death due to possible heart irradiation. Thereproducibility of the chest wall to heart distance in deep inspiration breath-hold (DIBH) was studied using a laser sensor with visual feedback. Methodology A total of 10 consecutive postoperative left-sided breast cancer cases receiving DIBH radiotherapy between December 2022 and September 2023 were retrospectively investigated. The prescribed dose was 50 Gy in 25 fractions. An Anzai respiratory gating system, AZ-733VI (Anzai, Tokyo, Japan), was employed that has a laser displacement sensor and a visual feedback device. An Elekta linac with a cone-beam CT unit, Axesse (Elekta AB, Stockholm, Sweden), was used in this study. The interfractional changes in the chest wall to heart distance among 25 fractions were analyzed for each of the 10 patients in each coordinate axis. In addition, the median with the 95% confidence interval (CI) and interquartile range (IQR) for all 250 fractions were calculated in each axis to assess the reproducibility of our DIBH technique. Results The medians of the interfractional changes in the chest wall to heart distance in each of the 10 patients ranged from -2 mm to 3 mm, -1 mm to 3 mm, and -2 mm to 1 mm in the lateral (X), superior-inferior (Y), and anterior-posterior (Z) directions, respectively. For all 10 cases, the medians were 1 mm (95% CI = 0.72 to 1.28 mm) in X, 1 mm (95% CI = 0.76 to 1.24 mm) in Y, and 0 mm (95% CI = -0.20 to 0.20 mm) in Z directions, whereas the IQRs were 4 mm in X, 2 mm in Y and 2 mm in Z directions. The measured IQRs were two to three times smaller than those shown in a previous report without visual feedback, suggesting a clinical advantage of the visual feedback in DIBH for left-sided breast cancer radiotherapy. The DIBH solution shown in this study required approximately 10 minutes from room-in to room-out, thereby not reducing the daily number of patients. Conclusions Our DIBH approach with visual feedback achieved better distance reproducibility between the chest wall and heart by a factor of two to three in terms of IQR compared to the previously reported data without visual feedback. Patient throughput was also favorable. To our knowledge, this is the first report demonstrating the chest wall to heart distance reproducibility in DIBH with visual feedback.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.