Abstract

Chest radiography is one of the most ubiquitous imaging modalities, playing an essential role in screening, diagnosis and disease management. However, chest radiography interpretation is a time-consuming and complex task, requiring the availability of experienced radiologists. As such, automated diagnosis systems for pathology detection have been proposed aiming to reduce the burden on radiologists and reduce variability in image interpretation. While promising results have been obtained, particularly since the advent of deep learning, there are significant limitations in the developed solutions, namely the lack of representative data for less frequent pathologies and the learning of biases from the training data, such as patient position, medical devices and other markers as proxies for certain pathologies. The lack of explainability is also a challenge for the adoption of these solutions in clinical practice.Generative adversarial networks could play a significant role as a solution for these challenges as they allow to artificially create new realistic images. This way, new synthetic chest radiography images could be used to increase the prevalence of less represented pathology classes and decrease model biases as well as improving the explainability of automatic decisions by generating samples that serve as examples or counter-examples to the image being analysed, ensuring patient privacy.In this study, a few-shot generative adversarial network is used to generate synthetic chest radiography images. A minimum Fréchet Inception Distance score of 17.83 was obtained, allowing to generate convincing synthetic images. Perceptual validation was then performed by asking multiple readers to classify a mixed set of synthetic and real images. An average accuracy of 83.5% was obtained but a strong dependency on reader experience level was observed. While synthetic images showed structural irregularities, the overall image sharpness was a major factor in the decision of readers. The synthetic images were then validated using a MobileNet abnormality classifier and it was shown that over 99% of images were classified correctly, indicating that the generated images were correctly interpreted by the classifier. Finally, the use of the synthetic images during training of a YOLOv5 pathology detector showed that the addition of the synthetic images led to an improvement of mean average precision of 0.05 across 14 pathologies.In conclusion, the usage of few-shot generative adversarial networks for chest radiography image generation was shown and tested in multiple scenarios, establishing a baseline for future experiments to increase the applicability of generative models in clinical scenarios of automatic CXR screening and diagnosis tools.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.