Abstract

10 homeopathic remedies commercially available (each in 3 dilutions) as sugar granules, where half of them were of organic (and half inorganic) origin were subjected to solid-state infrared spectroscopy, both in middle infrared (ATR-FTIR) and near infrared (NIR) range. Measurements were repeated six times (six days, each sample was measured once in the same day, samples were measured in random order). The obtained spectra was subjected to unsupervised (PCA) and supervised (PLS-DA) chemometric techniques to check any visible differnces in spectral data between homeopathic remedies, including also feature selection approaches. It can be concluded that the only one information encoded in this dataset is the atmospheric drift of spectra between consecutive measurement days. This proves that homeopathy is not “infrared visible” in the case of proper experimental design. These results can be useful in further investigations of possible mechanisms of action of homeopathy (if they exist).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.