Abstract

A new chemiluminescence method is described for the determination of 6-mercaptopurine. In the presence of tris(2,2’-bipyridine)ruthenium(II), 6-mercaptopurine (6MP) and hydrogen peroxide, upon the addition of hydroxide ion, resulted in intense light emission. The emission intensity is greatly enhanced by the presence of Tween-20. The linear range and detection limit of 6MP are 1.4×10-5− 1.4×10-g g/ml and 3×l0-10 g/ml, respectively. The method was evaluated by carrying out an interference study with common excipients and other coexisting compounds, by a recovery study and by the analysis of commercial formulation. A satisfactory result was obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.