The positive tone deep ultraviolet resist UV II HS-0.6 (Shipley) has been evaluated for ion exposure in the ion projector at the Fraunhofer Institute in Berlin. The chemically amplified resist showed extremely high sensitivity of 1×1012 H+ ions/cm2 at an ion energy of 75 keV. The contrast number was 11. Smallest lines with 65 nm linewidth could be delineated in 140-nm-high resist. At higher resist thickness of 370 nm, lines down to 70 nm were stable showing aspect ratios of >4. The exposure latitude at 100 nm nominal linewidth was ±10% dose variation for a ±10% linewidth change.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.