Chemical looping combustion experiments have been conducted in the 150kW CLC reactor at SINTEF Energy Research in Trondheim with good results. Methane was used as fuel and porous copper oxide based particles, with a bulk density of 800kg/m3 were, used as oxygen carrier. At a fuel power of 140kW the methane conversion was limited to about 90%, but at 100kW a methane conversion of up to about 98% was achieved with an oxygen deficit of about 3% compared to the stoichiometric amount. At the same time, the specific fuel reactor inventory was just above 120kg/MW, which is low compared to data found in the literature. The total active inventory in both reactors together was then 44kg and the overall excess air ratio was about 1.2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.