Abstract
One floor of a large office building in the Ottawa area was monitored during a month-long recarpeting project in which nylon carpet and latex adhesive were used. Total volatile organic compound (TVOC) samples were collected in several locations at various times after recarpeting. The TYOC concentration due to the recarpeting process showed the expected exponential decrease with time. Emission rates calculated from TYOC concentrations and measured air change rates agreed well with values determined in laboratory studies, and were much greater than the emission rate of the carpet alone. Information was collected that provided a link between symptoms of occupant discomfort and exposure to the recarpeting process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.