Grey cast iron metal strips were allowed to rust in varying compositions of soil-water media under the controlled environment. The process of corrosion was monitored by non-electrochemical method. Assessment of the extent of corrosion was carried out, both visually and by the method of weight loss coupons. It was found that a 80:20 weight:volume percent (w/v %) composition caused the most severe case of corrosion over a period of seven days. It was also observed that the corrosion in cast iron obeyed the relation, D = ktn [10]. The value of ‘n’ increased as corrosion became more severe. Gravimetric analysis and evidence from the Scanning Electron Microscopy (SEM) proved that γ-FeOOH was one of the intermediates of corrosion in grey cast iron in soil-water media. An attempt has also been made to propose a mechanism for the corrosion in cast iron strips in soil-water media. It was found to be consistent with the one proposed by McEnaney and Smith [11].

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.