Abstract
Chromatographic separation of styrene–methyl methacrylate (MMA) copolymers depending on the chemical composition was studied using liquefied carbon dioxide as an adsorption promoting solvent, and tetrahydrofuran, chloroform containing ethanol as a desorption promoting solvent in the mobile phase and the column packed with non-bonded silica gel by a solvent gradient method. With the increase of MMA content, the elution was retarded indicating that the typical normal-phase type of adsorption occurred. The effects of type of desorption solvents, molecular mass of sample, and column temperature on the elution were investigated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.