Abstract

Providing NFPA 1403 compliant live-fire training can present thermal and chemical exposure risk to instructors and students. To reduce risk, training academies, fire departments, instructors, and standards setting technical committees need more information on how different training fuels used in common training structures can impact the environment in which firefighter training occurs. This study utilized a traditional concrete training structure with multiple compartments to characterize training environments with three different fuel package materials [i.e., low density wood fiberboard, oriented strand board (OSB), and wood pallets]. Exposure risks for a fire instructor located on either the first or second floor were characterized using measurements of heat flux, air temperature and airborne concentrations of several contaminants including known, probable, or possible carcinogens. It was hypothesized that utilizing a training fuel package with solid wood pallets would result in lower concentrations of these airborne contaminants [aldehydes, polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs)] than wood-based sheet goods containing additional resins and/or waxes. Additionally, it was hypothesized that these concentrations would be lower than in the single compartment Fire Behavior Lab presented in a companion manuscript. For all measured compounds other than hydrochloric acid, airborne concentrations were 10 to 100 times lower than in the Fire Behavior Lab. OSB-fueled fires produced the highest median concentrations of total PAHs and VOCs such as benzene, while the pallet fuel package produced the lowest median concentrations of these compounds. These trends generally followed the qualitative visual obscuration created by each fuel. Additional tests were conducted on the OSB-fueled fires with increased ventilation and an alternate means of reducing visibility through smoldering smoke barrels. This OSB experiment with increased ventilation resulted in the highest temperatures in the fire room but the lowest impact on visibility throughout the structure, as well as the lowest overall concentrations of contaminants in this study. In contrast, the smoldering straw-filled smoke barrel created a highly obscured environment (with minimal impact on thermal environment) and some of the highest concentrations of the targeted contaminants of any test. These data may be useful in balancing obscuration for training with potential exposure to thermal stressors and contaminants.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.