Abstract
A semi-analytical modulation scheme to operate a single-phase, single-stage dual active bridge (DAB) AC-DC converter under full-operating-range zero voltage switching (ZVS) is proposed. The converter topology consists of a DAB DC-DC converter, receiving a rectified AC line voltage via a synchronous rectifier. ZVS modulation strategies previously proposed in literature are either based on current-based (CB) or energy-based (EB) ZVS analyses. The combined phase-shift, duty-cycle, and switching frequency modulation proposed in this paper relies on a novel, current-dependent charge-based (CDCB) ZVS analysis, taking into account the commutation charge of the (parasitic) switch capacitances as well as the time dependency of the commutation currents. Thereby, commutation inductance is shown to be an essential element in achieving full-operating-range ZVS. Experimental results obtained from a 3.7 kW bidirectional electric vehicle battery charger which interfaces a 400 V DC-bus with the 230 Vac, 50 Hz utility grid are given to validate the analysis and practical feasibility of the proposed strategy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.