In this article, the longitudinal beam bunch behaviors of the Hefei Light source-II (HLS-II) are effectively investigated and analyzed based on the beam multi-parameter measurement system. Simultaneously, the temporal beam characteristic parameter extraction (T-BCPE) method is developed for measuring the longitudinal impedances of machine. In the case of 100.4 kV radio-frequency (RF) voltage, the inductance and resistance in the longitudinal coupling impedance of HLS-II are obtained as 115 ± 13 nH and 1320 ± 310 Ω by extracting bunch lengthening factor and asymmetry factor, respectively. In addition, the longitudinal beam dynamical characteristics and potential-well distortion are also in-depth analyzed above the threshold current of the microwave instability. As a result, the longitudinal broadband impedance of HLS-II is measured to be 8.94 ± 0.44 Ω while 0.339 ± 0.004 of the scaling factor in combination with the theoretical analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.