Abstract

Devices under semi-on-state stress often suffer from more severe current collapse than when they are in the off-state, which causes an increase in dynamic on-resistance. Therefore, characterization of the trap states is necessary. In this study, temperature-dependent transient recovery current analysis determined a trap energy level of 0.08 eV under semi-on-state stress, implying that interface traps are responsible for current collapse. Multi-frequency capacitance–voltage (C-V) testing was performed on the MIS diode, calculating that interface trap density is in the range of 1.37×1013 to 6.07×1012cm−2eV−1 from EC−ET=0.29 eV to 0.45 eV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.