Abstract
The retention characteristics of all 209 polychlorinated biphenyl (PCB) congeners were determined on a new p,p-cyanobiphenyl stationary phase using gas chromatography with electron capture detection (GC-ECD). Response factors were determined relative to decachlorobiphenyl, PCB 209. Several congeners that coelute on the phases routinely used for PCB analysis are separated on this phase, including the hexachlorobiphenyls 138, 163, and 164. The p,p-cyanobiphenyl stationary phase exhibits altered retention for planar congeners, such that the toxic coplanar PCBs 77, 126, and 169 are eluted free from interference. Of the 209 congeners, 61 were separated using the p,p-cyanobiphenyl phase in conjunction with GC-ECD. When analyzed by gas chromatography with mass selective detection (GC-MSD), the number of congeners determined increased to 133. Therefore GC-MSD was used with the p,p-cyanobiphenyl phase to characterize three PCB mixtures: Aroclor 1242, Aroclor 1254, and Aroclor 1260.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.