Abstract

Over the past decade chemical processing and engineering of musculoskeletal tissue (tendon and bone) has improved dramatically. The use of bone allograft and xenograft in reconstructive orthopedic and maxillofacial surgeries is increasing, yet severe complications can occur if the material is contaminated in any way. A novel tissue sterilization process, BioCleanse®, has been developed to clean and sterilize musculoskeletal tissue for implantation. The present study was designed to determine the effect of this novel cleaning process on the biomechanical properties of bovine cortical bone prior to implantation. The mechanical properties of treated bovine bone material were compared to human samples with respect to failure under compression, shear and three-point bending. The data demonstrate that bovine bone treated with the novel sterilization procedure has favorable biomechanical properties compared to that of human bone treated in a similar fashion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.