Abstract

Cleaning work using spray products has been associated with adverse respiratory effects but little is known of the exposure concentrations. The purpose of this study was to characterize aerosol generation at spray scenarios in a controlled climate chamber. Spraying on vertically and horizontally oriented surfaces, as well as spraying on a cloth, was investigated. Furthermore, the effect of nozzle geometry was tested. The average mass generation rates of six pressurized spray cans and 13 trigger sprays were about 1.7g/s and did not differ significantly, but the average values of the individual sprays had large variations (0.5-3.1g/s). The time required to halve the air concentration of aerosol particles, the half-life time, was determined for all spray products. The average half-life time of the total particle mass concentration (TPMC) of the pressurized spray cans was 0.5h versus 0.25h for trigger sprays. Gravimetrically determined airborne fractions of pressurized spray cans tended to be higher than those of trigger sprays. However, airborne fractions based on the measured peak TPMC were up to three orders of magnitude smaller. A comparison of different trigger spray nozzles when spraying the same product showed that the TPMC can be up to 18 times higher for the largest emitting nozzle. The distance of the nozzle to a cloth should be 1cm to significantly reduce the concentration of the generated aerosols. ConsExpo modeling predicted the measured peak TPMC well but less well the decay.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call