Abstract

Submicrometer and especially fine aerosols that enter the respiratory tract are largely exhaled. However, the deposition of these aerosols under expiratory conditions is not well characterized. In this study, expiratory deposition patterns of both ultrafine (<100 nm) and fine (100–1000 nm) respiratory aerosols were numerically modeled in a realistic nasal-laryngeal airway geometry. Particle sizes ranging from 1 through 1000 nm and exhalation flow rates from 4 through 45 L/min were considered. Under these conditions, turbulence only appeared significant in the laryngeal and pharyngeal regions, whereas the nasal passages were primarily in the laminar regime. Exhaled particles were simulated with both a continuous-phase drift flux velocity correction (DF-VC) model and a discrete Lagrangian tracking approach. For the deposition of ultrafine particles, both models provided a good match to existing experimental values, and simulation results corroborated an existing in vivo–based diffusion parameter (i.e., D 0....