Abstract

To explore a way to characterize fatigue damage degree of ferromagnetic materials by metal magnetic memory testing (MMMT), tension-compression fatigue test of specimens with different stress concentration factors made of 45% C steel were carried out. Both normal and tangential component of magnetic memory signals, Hp(y) and Hp(x), of specimens under different fatigue cycles were measured by EMS-2003 and RM-1 magnetic memory testing apparatus respectively. The results show that, the gradient variation of Hp(y) signals during the fatigue test is similar to each other, but the gradient value is different due to the different stress concentration factors. And so is the relative peak value of Hp(x) signals. Both gradient of Hp(y) and relative peak value of Hp(x) can be used to distinguish the stress concentration degree of specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.