Abstract

Recent developments in the domain of the standard CMOS imagers for visible light, mainly in the reduction of the pixel size, has led us to investigate the suitability of some of these devices as ionizing radiation detectors. A standard 640x480 imager with 5.6x5.6 micrometer pixel size (Aptina product MT9SH06) has been characterized with X-ray (55Fe and 8 keV X-ray tube) and charged particles sources (500 MeV electrons). The main results obtained are: a small average pixel multiplicity (4-5), for the detection of either X-ray or charged particles; a good linearity of the response; a S/N ratio of 29 for a Minimum Ionizing Particle and an estimated sensitivity to X-rays down to 1 keV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.