Abstract

In this study, tantalum carbide films deposited by a sputtering process with a TaC target as diffusion barriers for Cu metallization were investigated for the first time. The thermal stability of and systems as a function of annealing temperature are reported and analyzed. The deposited , having an amorphous structure and a low resistance of around 385 μΩ cm, were characterized by sheet resistance measurement, X‐ray diffraction (XRD), X‐ray photoelectron spectroscopy, scanning electron microscopy (SEM), secondary ion mass spectroscopy, and diode leakage current measurement. From XRD and SEM analysis, it was found that in structure can effectively prevent Cu penetration up to 600°C for 30 min, while more sensitive diode leakage measurement of indicates that the failure temperature is around 500°C. The failure of the layer was found to be mainly due to the diffusion of Cu along the localized defects of the barrier layer into underlying silicon. This has caused the formation of copper silicides and high junction leakage currents. © 2000 The Electrochemical Society. All rights reserved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.