Abstract

Magnetic resonance imaging (MRI) is capable of distinguishing between atherosclerotic plaque components solely on the basis of biochemical differences. However, to date, the majority of plaque characterization has been performed by using high-field strength units or special coils, which are not clinically applicable. Thus, the purpose of the present study was to evaluate MRI properties in histologically verified plaque components in excised human carotid endarterectomy specimens with the use of a 5F catheter-based imaging coil, standard acquisition software, and a clinical scanner operating at 0.5 T. Human carotid endarterectomy specimens from 17 patients were imaged at 37 degrees C by use of an opposed solenoid intravascular radiofrequency coil integrated into a 5F double-lumen catheter interfaced to a 0.5-T General Electric interventional scanner. Cross-sectional intravascular MRI (156x250 microm in-plane resolution) that used different imaging parameters permitted the calculation of absolute T1and T2, the magnetization transfer contrast ratio, the magnitude of regional signal loss associated with an inversion recovery sequence (inversion ratio), and regional signal loss in gradient echo (gradient echo-to-spin echo ratio) in plaque components. Histological staining included hematoxylin and eosin, Masson's trichrome, Kossa, oil red O, and Gomori's iron stain. X-ray micrographs were also used to identify regions of calcium. Seven plaque components were evaluated: fibrous cap, smooth muscle cells, organizing thrombus, fresh thrombus, lipid, edema, and calcium. The magnetization transfer contrast ratio was significantly less in the fibrous cap (0.62+/-13) than in all other components (P<0.05) The inversion ratio was greater in lipid (0.91+/-0.09) than all other components (P<0.05). Calcium was best distinguished by using the gradient echo-to-spin echo ratio, which was lower in calcium (0.36+/-0.2) than in all plaque components, except for the organizing thrombus (P<0.04). Absolute T1 (range 300+/-140 ms for lipid to 630+/-321 ms for calcium) and T2 (range 40+/-12 ms for fresh thrombus to 59+/-21 ms for smooth muscle cells) were not significantly different between groups. In vitro intravascular MRI with catheter-based coils and standard software permits sufficient spatial resolution to visualize major plaque components. Pulse sequences that take advantage of differences in biochemical structure of individual plaque components show quantitative differences in signal properties between fibrous cap, lipid, and calcium. Therefore, catheter-based imaging coils may have the potential to identify and characterize those intraplaque components associated with plaque stability by use of existing whole-body scanners.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call