Abstract

Abstract Single point incremental forming (SPIF) is a relatively new manufacturing process that has been recently used to form medical grade titanium sheets for implant devices. However, one limitation of the SPIF process may be characterized by dimensional inaccuracies of the final part as compared with the original designed part model. Elimination of these inaccuracies is critical to forming medical implants to meet required tolerances. Prior work on accuracy characterization has shown that feature behavior is important in predicting accuracy. In this study, a set of basic geometric shapes consisting of ruled and freeform features were formed using SPIF to characterize the dimensional inaccuracies of grade 1 titanium sheet parts. Response surface functions using multivariate adaptive regression splines (MARS) are then generated to model the deviations at individual vertices of the STL model of the part as a function of geometric shape parameters such as curvature, depth, distance to feature borders, wall angle, etc. The generated response functions are further used to predict dimensional deviations in a specific clinical implant case where the curvatures in the part lie between that of ruled features and freeform features. It is shown that a mixed-MARS response surface model using a weighted average of the ruled and freeform surface models can be used for such a case to improve the mean prediction accuracy within ±0.5 mm. The predicted deviations show a reasonable match with the actual formed shape for the implant case and are used to generate optimized tool paths for minimized shape and dimensional inaccuracy. Further, an implant part is then made using the accuracy characterization functions for improved accuracy. The results show an improvement in shape and dimensional accuracy of incrementally formed titanium medical implants.

Highlights

  • Titanium is the material of choice in class III medical implants due to its biological inertness, strength, lightweight nature, bio-compatibility, and low-cost production [1]

  • The results show an improvement in shape and dimensional accuracy of incrementally formed titanium medical implants

  • This is done by studying the accuracy behavior of ellipsoidal shapes formed using single point incremental forming (SPIF), which is one of the process variants of incremental sheet forming (ISF)

Read more

Summary

Introduction

Titanium is the material of choice in class III medical implants due to its biological inertness, strength, lightweight nature, bio-compatibility, and low-cost production [1]. The work of Göttmann [3] illustrated the ability to form implants with a maximum deviation at the edges just less than 2 mm using two point incremental forming (TPIF) Despite these efforts, no definite characterization of freeform surfaces and titanium implants made by ISF is currently available. To overcome the limitations of the current accuracy characterization techniques, an effort is made in this work to generate accuracy response surfaces for freeform shapes This is done by studying the accuracy behavior of ellipsoidal shapes formed using single point incremental forming (SPIF), which is one of the process variants of ISF.

Accuracy characterization methodology
Model parameters
Experimental details
Feature detection thresholds
Model for freeform ellipsoidal parts
Model for ellipse draft ruled surfaces
Generalized model for a part with mixed curvatures
Test geometries
Model validation results
Compensation technique
Accuracy of compensated implant
Limitations and discussion on the developed models
Conclusions