Abstract
Two reciprocating membranes (rMBR) with two frequencies of 0.46 Hz (rMBR-0.46) and 0.3 Hz (rMBR-0.3) were operated to compare the treatment performance and gross energy consumption with a conventional MBR. The average organic removal rates of MBR, rMBR-0.46 and rMBR-0.3 were maintained 295 ± 51; 823 ± 296; and 397 ± 129 mgCOD/gVSS.d, respectively. Nitrogen removal was enhanced in rMBR phases compared to conventional MBR phase due to anoxic membrane chamber. Further, fouling rate was found to be highest of 16.5 mbar/day (at conventional MBR phase), which was and much decreased to1.0 mbar/day (at rMBR-0.46 phase) and then 0.2 mbar/day (rMBR-0.3 phase). The reciprocation membrane also showed energy potential by saving 10.6% electricity for each treated cubic meter of wastewater compared to the conventional MBR.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.