Abstract

Polymerized impurities in β-lactam antibiotics can induce allergic reactions, which seriously threaten the health of patients. In order to study the polymerized impurities in cefoxitin sodium for injection, a novel approach based on the use of two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry (2D-LC-TOF MS) was applied. In the 1st dimension, high performance size exclusion chromatography (HPSEC) with a TSK-G2000SWxl column was employed. Column switching was applied for the desalination of the mobile phase used to separate polymerized impurities in the 1st dimension before they were transferred to the 2nd dimension which utilized reversed phase liquid chromatography (RP-LC) and TOF MS for further structural characterization. The structures of four polymerized impurities (which were all previously unknown) in cefoxitin sodium for injection were deduced based on the MS2 data. One novel polymerized impurity (PI–I), with 2H less than the molecular weight of two molecules of cefoxitin (Mr. 852.09), was found to be the most abundant (>50 %) in almost all the samples examined and could be regarded as the marker polymer of cefoxitin sodium for injection. This work also showed the great potential of the 2D-LC-TOF MS approach in structural characterization of unknown impurities separated with a mobile phase containing non-volatile phosphate in the 1st dimension.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call