Abstract

Abstract In this paper we present the results and description of a system used to characterize the performance ofmid-temperature solar thermal collectors without using flow rate or heat capacity measurements. For this demonstration, we implement a testing stand using mineral oil as the heat transfer fluid. Twogenerations of CPC assisted, non-tracking evacuated solar thermal collector are tested up to 230 °C and presented. All three generations consist of metal glass evacuated tubes. The results show that byreducing the thermal resistance between the heat transfer fluid and selective coating and promoting higher concentration ratios using non-tracking concentrators, an evacuated tube CPC solar array can achieve 50% efficiency at 200 degree Celsius under a one sun condition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.