Abstract

Low Drop-Out (LDO) voltage regulators are extensively used to provide a stable power supply voltage independent of load impedance. LDO must be robust with regard to input voltage, temperature and local mismatch variations. Moreover, it must fulfill these specifications all along its lifetime. The influence of process variation on LDO performances has intensively been studied, but only few works are reported about ageing mechanisms. This paper presents an illustrative case study on the change of LDO performances due to wear-out mechanisms. The ageing effects are investigated on the static and dynamic performances parameters. After introducing LDO design content, a review of degraded performances (Output Voltage VOUT, Power Supply Rejection Ratio (PSRR), shutdown current…) is presented and compared to simulation. Then, statistical VOUT measurements are presented and compared with Monte Carlo simulations. Finally, sizing for yield methodology is introduced. The objective is to find optimal device size to guarantee a target of failure rate in fresh and aged conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.