Abstract

We examined the relationship between long-term femoral-head-penetration patterns and osteolysis in a ten-year follow-up study of a well controlled patient population. The purposes of this study were to characterize the linearity of long-term head-penetration patterns over time, to describe the relationship between ten-year true wear rates and osteolysis, and to determine whether the occurrence of osteolysis at ten years could be predicted by penetration data obtained prior to five years. Temporal femoral-head-penetration patterns were examined at a minimum of ten years after forty-eight primary total hip arthroplasties. The arthroplasties were performed with the use of an Arthropor acetabular cup (Joint Medical Products) and a thirty-two-millimeter-diameter cobalt-chromium femoral head (DePuy). Using a computer-assisted radiographic technique, we evaluated two-dimensional head penetration on serial annual radiographs. Linear regression analysis modeled penetration-versus-time data as a line for each patient. The slope of the regression line indicated the true wear rate for each patient. In a subgroup of thirty-four hips for which three annual radiographs had been made less than five years after the arthroplasty, we compared early head-penetration patterns with the later occurrence of osteolysis. For all forty-eight hips, the true wear rate averaged 0.18 millimeter per year (range, 0.01 to 0.44 millimeter per year) and temporal head-penetration patterns tended to be linear (mean r2 = 0.91 +/- 0.16). Osteolysis at ten years was strongly associated with increasing true wear rates (p < 0.001). Osteolysis did not develop in any of the nine hips with a true wear rate of less than 0.1 millimeter per year. However, osteolysis developed in nine (43 percent) of twenty-one hips with a rate between 0.1 and less than 0.2 millimeter per year, in eight of ten hips with a rate between 0.2 and 0.3 millimeter per year, and in all eight hips with a rate of greater than 0.3 millimeter per year. Evaluation of early true wear rates as a predictor of late osteolysis showed a similar relationship. This study demonstrates that true wear rates tend to be constant and that increased true wear is significantly associated with osteolysis at ten years after the operation. A similar relationship was also found at the early follow-up interval, indicating that early true wear rates (determined from serial radiographs) might enable orthopaedists to predict if patients are at risk for the development of osteolysis. On the basis of these findings, we use temporal femoral-head-penetration data in our practice to evaluate polyethylene inserts in asymptomatic patients, to estimate the time to component wear-through, and to adjust the frequency of follow-up evaluations for monitoring the development of osteolytic lesions in at-risk patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.