Abstract

The paper investigates both local and global capacity criteria for collapse assessment of RC frame buildings. Both literature and regulations criteria are considered, also including the formulation recommended in the draft of the new Eurocode 8 (part 3) and other collapse criteria never investigated. The case studies consist of low-rise bare and infilled frame buildings, which are designed according to the Italian code provisions considering low-to-high seismicity sites in Italy. The seismic demand is estimated by performing multiple-stripe analysis based on inelastic modeling, also including the presence of the infills. The capacity assessment and the performance evaluation associated with the (building) collapse are carried out according to the latest approaches and methodologies of performance-based earthquake engineering. The investigated capacity criteria are characterized as a result of the collapse assessment in terms of (a) collapse demand to capacity ratios, (b) collapse fragility curves, (c) collapse margin ratios and probabilities, and (d) inter-capacity margin ratios. The findings provide novel information and technical insights into the influence of the collapse capacity criteria selection on the collapse features of the investigated buildings. In particular, the capacity criteria are quantitatively correlated to the building collapse performance, also outlining safety and economic considerations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call