Abstract

Leaky faults provide important flow paths for fluids to move underground. It is often necessary to characterize such faults in engineering projects such as deep well injection of waste liquids, underground natural gas storage, and radioactive waste isolation. To provide this characterization, analytical solutions are presented for groundwater flow through saturated aquifer‐fault‐aquifer systems assuming that both the aquifers and the fault are homogeneous and that the fault has an insignificant effect on aquifer hydraulic properties. Three different conditions are considered: (1) drawdown in the unpumped aquifer is negligibly small; (2) drawdown in the unpumped aquifer is significant, and the two aquifers have the same diffusivity; and (3) drawdown in the unpumped aquifer is significant, and the two aquifers have different diffusivities. Methods are presented to determine the fault transmissivity from pumping test data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.