Abstract

AbstractTo meet the requirements of development in heat exchangers design, the effect of different tubes geometrical parameters on its flow field analysis and thermal heat transfer performance are investigated in the current research work. The hydraulic thermal fluid coupling with computational simulations is applied. The numerical results are solving used flow transport and heat transfer equations, then these results are validated with available experimental data. The behavior of hydraulic and thermal flow in the corrugated tube is discussed with different geometrical parameters' position and shape. Turbulent flow in the tube is calculated in three‐dimensional numerical simulations with optimization of a multiobjective algorithm are analyzed. The influences of various design parameters, for instance, the number of corrugated rings around the tube, distance between each corrugated ring, the diameter of the ring, and pitch of ring are investigated firstly in the flow field and then optimized by using the design of experiment (DOE). The influence of flow structural modifications such as static pressure, dynamic pressure, and pressure drop is taken into consideration as analyzed performance parameters. The DOE method is investigated based on implements and variances the L16 orthogonal arrays are chosen as the experimental strategy. Furthermore, the optimization results found that the maximum value of pressure difference was for corrugated diameter. The numerical method using DOE has enhanced heat transfer rate as compared to the smooth pipe. Moreover, the minimum Tout is for Case 11 (296.49°C) and the maximum Tout is for (303.10°C) hence the value of Nu number for both cases is 32.9 and 42, respectively. That means using this type of passive device can improve the heat transfer in the pipe. The outcomes illustrate that the performance evaluation factor (PEF) ratio of the corrugated pipe with different geometrical configurations is changed and increased as the corrugated pipe geometrically changed and the value of PEF is more than 1.3.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.