Abstract

To improve the mechanical properties of pure hydroxyapatite (HA) ceramics and pure 45S5 bioglasses, HA–316L fibre composites and bioglass 45S5–316L fibre composites were produced by spark plasma sintering (SPS) at 950 and 850 °C, respectively. While the HA phase in the HA–316L fibre composites did not decompose after the SPS process, microcracks were found around the 316L fibres in the composites. Consequently, the HA–316L fibre composites could not effectively improve the mechanical properties of the pure HA ceramics. In contrast, the bioglass 45S5–316L fibre composites showed no microcracks around the 316L fibres and thus exhibited bending strengths of up to 115 MPa.