Abstract

The aim of the work reported in this paper was to study the characterization of fluid machines (e.g., fans, pumps) as sources of fluid-borne sound in connected pipe or duct systems. Of special interest is the possibility of extending earlier published methods beyond the plane wave region: i.e., to include higher order modes effects. For machines which can be modelled as an acoustic multi-port source, a method which makes it possible to measure the source data is suggested together with a modal decomposition technique. In order to verify and test the measurement method and modal decomposition technique, measurements were first carried out on a small test-rig without flow, with an ordinary loudspeaker as a source. Then the method was tested on an axial fan mounted to the end of a duct. In both cases ten microphone positions, divided equally between two duct cross-sections, were used to separate the waves (five modes) into left- and right-going components. It was verified that the measured source data can be used to predict the sound field created by the fan at a given acoustic load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.