Abstract

Electrostatic actuators are one of the most promising devices for mirror control in advanced gravitational waves detectors. An accurate characterization of such actuators is required for a correct design, able to satisfy the requirement of the control system, both in term of low noise content as well as to fit the required dynamic range. To this aim a simple and effective experimental set-up was developed, consisting in a suspended mirror which displacement, induced by an electrostatic actuator, is measured by using an optical lever. The effect of stray patch charge on the mirror was minimized by using an alternate voltage as bias reference for the actuator. Different working conditions were investigated, in particular by varying the mirror-actuator distance and the bias amplitude. The experimental results were compared to the prediction of a numerical model taking into account the actuator geometry and the working conditions.