Abstract

AbstractAtmospheric‐pressure dielectric barrier discharge (DBD) in air is investigated for medical applications, especially for skin treatment. When the DBD was tested on mouse skin, a homogeneous discharge accompanied by filamentary microdischarges is observed. For characterization of the homogeneous discharge, averaged plasma parameters (namely electron density and electron velocity distribution function) and gas temperature are determined by optical emission spectroscopy, microphotography and numerical simulation. Chemical kinetics in the active plasma volume and in the afterglow is simulated. Fluxes of biologically useful molecules like nitric oxide (NO) and ozone reaching the treated surface and irradiation by UV photons are determined. Skin biopsy results show that DBD treatment causes no inflammation and no changes in the skin‐collagen. magnified image

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.