Abstract

Cryogen spray cooling (CSC) has been used effectively to protect the epidermis during laser dermatologic surgery. However, the temperature reduction in human skin induced by CSC has not been reliably determined due to the short cooling period and significant temperature gradient in the skin. Therefore, CSC has not been optimized for different laser dermatologic surgery procedures. Although it would be desirable to measure in situ human skin temperature, embedding a sensor within 100 μm beneath the skin surface is not feasible. In addition, infrared skin temperature measurement is also not workable because the skin is covered with a cryogen layer of unknown thickness. In this study, we selected an epoxy which has similar thermal properties to that of human skin as our cooling target. Thin-film thermocouples (TFTC) were deposited directly onto the epoxy substrate using micro-fabrication techniques to minimize the thermal contact resistance between TFTC and the substrate. The negligible mass of TFTC also creates a minimal disturbance to heat flow across the surface. Due to the difference in thermoelectric property between thin film and leading wire, special sensor design and calibration procedures were developed. TFTC were calibrated from −46 to 50°C. The thermoelectric sensitivity is around 50–60% of that of bulk material. Skin phantom temperature reductions produced by a commercial medical laser nozzle at different spray durations were measured using the TFTC. The results not only help to elucidate the mechanisms involved in interaction between cryogen spray and human skin but also provide a thermal boundary condition for numerical modeling of laser dermatologic surgery.

Highlights

  • Pulsed laser is the treatment of choice for vascular birthmarks, such as port wine stains and hemangiomas

  • We found that when the film thickness is less than 1 μm, EMF may be generated when the Ni strip is cooled with cryogen spray

  • Effect of Spurt Duration We have carried out cryogen spray cooling (CSC) experiments with a nozzle from a commercial medical laser (GentleLase, Candela, MA)

Read more

Summary

Introduction

Pulsed laser is the treatment of choice for vascular birthmarks, such as port wine stains and hemangiomas. CSC heat flux derived from temperature measurement with conventional wire thermocouples embedded in different substrates (epoxy, copper, etc.) ranges from 75 – 1,100 kW/m2 [3,4,5,6,7]. Thin-film thermocouples (TFTC) were developed for temperature measurements during CSC.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.