Abstract

Abstract This paper forms part of a study aimed at the development of a procedure for the determination of heavy metals in compost. The present paper deals with the sample preparation stage, including subdividing laboratory samples and reduction of the particle size. The effect of particle size reduction on the random error due to the analysis of test portions was examined. It was found that milling for 20min in a quartz planet ball mill yields sufficiently homogeneous test samples. As the milling capacity of this device is too small, prior to milling subdivision of the laboratory sample is required. Subdivision before drying is recommended for practical reasons.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.