Abstract

Abstract An austenitic stainless steel (AISI 304) pipe weldment, which had been in operation about 45,000 h at 230°C in the Ringhals 1 BWR plant, was characterized using electrochemical sensitization testing methods (electrochemical potentiokinetic reactivation [EPR] and double-loop EPR), as well as transmission electron microscopy. The weld heat-affected zone (HAZ) showed a sensitized zone between two and five mm from the fusion line in which grain boundary carbides formed almost a continuous chain, and Cr-depletion was evident.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.