Abstract

During quality control of doxofylline, a novel impurity was detected, which was above the identification threshold defined by ICH. First, a liquid chromatographic method compatible with mass spectrometric (MS) detection was developed. Based on tandem multistage MS and high resolution MS data, the unknown impurity was found to consist of two theophylline groups connected by a methylene group. The structure was further confirmed by 1D and 2D nuclear magnetic resonance (NMR) experiments after semi-preparative isolation. In addition, the formation of the impurity was also discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.