Abstract

The storage and use of explosives is regulated at the state and federal level, with a particular focus on physical security and rigorous accounting of the explosive inventory. For those working with explosives for the training and testing of explosive-detecting canines, cross-contamination is an important concern. Hence, explosives intended for use with canine teams must be placed into secondary storage containers that are new, clean, and airtight. A variety of containers meet these requirements and include screw-top glass jars (e.g., mason jars). However, an additional need from the explosive-detecting canine community is secondary containers that can also be used as training aids whereby the volatiles emitted by explosives are emitted in a predictable and stable manner. Currently, a generally accepted method for the storage of explosives and controlled emission of explosive vapor for canine detection does not exist. Ideally, such containers should allow odor to escape from the training aid but block external contaminates such as particulates or other volatiles. One method in use places the explosive inside a permeable cotton bag when in use for training and then stores the cotton bag inside an impermeable nylon bag for long-term storage. This paper describes the testing of an odor permeable membrane device (OPMD) as a new way to store and deploy training aids. We measured the evaporation rate and flux of various liquid explosives and volatile compounds that have been identified in the headspace of actual explosives. OPMDs were used in addition to traditional storage containers to monitor the contamination and degradation of 14 explosives used as canine training aids. Explosives were stored individually using traditional storage bags or inside an OPMD at two locations, one of which actively used the training aids. Samples from each storage type at both locations were collected at 0, 3, 6, and 9months and analyzed using Fourier Transform Infrared (FTIR) Spectroscopy and Gas Chromatography-Mass Spectrometry (GC-MS) with Solid-Phase Microextraction (SPME). FTIR analyses showed no signs of degradation. GC-MS identified cross-contamination from ethylene glycol dinitrate (EGDN) and/or 2,3-dimethyl-2,3-dinitrobutane (DMNB) across almost all samples regardless of storage condition. The contamination was found to be higher among training aids that were stored in traditional ways and that were in active use by canine teams.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.