Abstract

Wavelength tuning is demonstrated in an antenna-coupled infrared microbolometer. With a 300-mV control voltage, we observed a tuning range of 0.5 µm near 10 µm. A metal-oxide-semiconductor capacitor underneath the antenna arms causes the shift of resonance wavelength with applied voltage. We develop a device model that agrees well with measured results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.